Create a circular outdoor fire feature with a finish that complements your patio. Warming Trends ready-to-finish kits pair an aluminum frame covered in concrete board with a matched CROSSFIRE brass burner and aluminum pan, leaving the stone or veneer choice to you. Select the frame size and fuel for your installation.
Key Features
- Unfinished concrete-board-covered aluminum frame ready for a suitable exterior veneer.
- CROSSFIRE brass burner and aluminum pan matched to the selected kit.
- Includes a Fire Pit Vent Kit, flex-line kit and 4-in key-valve extension.
- Natural gas and liquid propane versions; select the correct gas-specific kit.
Specifications
- FC42: CFB120 burner and 24-in pan. FC54: CFB180 burner and 30-in pan. FC60: CFB290 burner and 36-in pan. FC72: CFB350 burner and 48-in pan.
- Pan sidewalls: 2 in.
- Ignition systems are sold separately. Veneer, media and gas supply installation are not included.
- Store item codes: Natural Gas / 42 Inch — WTFC42NG; Natural Gas / 54 Inch — WTFC54NG; Natural Gas / 60 Inch — WTFC60NG; Natural Gas / 72 Inch — WTFC72NG; Liquid Propane / 42 Inch — WTFC42LP; Liquid Propane / 54 Inch — WTFC54LP; Liquid Propane / 60 Inch — WTFC60LP; Liquid Propane / 72 Inch — WTFC72LP.
Dimensions
- Unfinished frame diameter × height: FC42, 42 × 18 in; FC54, 54 × 18 in; FC60, 60 × 18 in; FC72, 72 × 18 in.
- Pan diameters: 24, 30, 36 or 48 in according to kit; each has 2-in sidewalls.
- Finished outside dimensions depend on the selected veneer; do not use the pan diameter as the frame diameter.
Compatibility & Installation
- Outdoor decorative fire-feature use only; this is not a cooking or grill burner. Keep food and solid fuels away.
- Have a qualified gas/plumbing professional verify fuel, supply capacity, connections, clearances and local-code requirements before installation.
- For match-lit operation, supply pressure must be 3.5–7.0 in W.C. for natural gas or 11.0–13.0 in W.C. for liquid propane.
- Use a stable, level, noncombustible enclosure with drainage, an accessible external gas shutoff and an unfilled lower cavity. The support structure, not the gas valve or line, must carry the assembly.
- Maintain at least 36 in horizontal clearance to combustibles, measured from the top of the flame as shown in the manual, and 84 in vertically above the burner/plate. Recess the assembly 4–6 in below the enclosure top; review the complete clearance diagram before building.
- Provide at least two opposing enclosure vents, each with at least 18 sq in of ventilation area. Larger enclosures or extended use may require more ventilation.
- Use only approved outdoor fire-feature media with pieces at least 1/2 in in size; cover jets by no more than 1/2 in of media. Place media onto the plate or pan instead of dumping it over the burner, and follow the complete manual. Remove any cover before lighting and let the feature cool completely before covering.
- Vents and key valves are not preinstalled. Have the contractor locate and install them on site to suit the veneer while preserving required ventilation and service access.
- Confirm the exact included burner and required ignition arrangement with your installer. Warming Trends recommends a manufacturer-approved ignition system whenever burner output exceeds 300,000 BTU.
Manufacturer Resources
Manufacturer contact: Warming Trends, 303-346-2224 or orders@warming-trends.com. Have the exact model, fuel and selected package available when confirming fit or service.