SKU: WTCFB240NG

Warming Trends CFB240 Original CROSSFIRE® Brass Burner

$897.00

Shipping calculated at checkout

Gas Type: Natural Gas

Available Now!

Make an outdoor fire pit a welcoming place to gather with the Warming Trends CFB240 Original CROSSFIRE brass burner. Its jet layout creates a full flame display for a decorative fire feature. Select the natural gas or liquid propane version to match your gas supply.

Key Features

  • Original CROSSFIRE brass burner designed for an outdoor decorative gas fire feature.
  • Multi-jet burner layout suited to a circular or square fire feature.
  • WATERSTOP fitting helps keep water and debris out of the gas line and downstream components.

Specifications

  • Burner model: CFB240; maximum manufacturer-rated output: 240,000 BTU.
  • Fuel: gas-specific natural gas (NG) or liquid propane (LP) version, according to the selected option.
  • Ignition: match-lit configuration; an automatic ignition system is not included.
  • Package: CFB240 gas-specific burner. Plate or pan is not included. Flex-line/key-valve kit is not included.
  • Store item codes: Natural Gas — WTCFB240NG; Liquid Propane — WTCFB240LP.

Dimensions

  • Burner footprint, viewed from above: 19 1/8 in × 21 1/8 in.
  • Manufacturer recommended minimum fire-feature opening: 30 in (circular or square).
  • Compatible plate size (plate sold separately): 30 in diameter circular.
  • The cited model drawing does not dimension total burner height; do not use the plate size as the burner size.

Compatibility & Installation

  • Outdoor decorative use only. This is not a cooking or grill burner; keep food and solid fuel away from the fire feature.
  • Have a qualified gas/plumbing professional verify fuel, supply capacity, connections and local-code requirements before installation.
  • For match-lit operation, supply pressure must be 3.5–7.0 in W.C. for natural gas or 11.0–13.0 in W.C. for liquid propane.
  • Use a stable, level, noncombustible enclosure with drainage, an accessible external gas shutoff and an unfilled lower cavity. The plate/support structure—not a valve or gas line—must carry the assembly.
  • Maintain at least 36 in horizontal clearance to combustibles, measured from the top of the flame as shown in the manual, and 84 in vertically above the burner/plate. Recess the assembly 4–6 in below the enclosure top; review the complete clearance diagram before building.
  • Provide at least two vents on opposing enclosure sides, each with at least 18 sq in of ventilation area. Larger or heavily used enclosures may need more ventilation.
  • Media, enclosure, support collars, cover, gas supply/regulation and automatic ignition are not included unless separately specified. Use only approved fire-rated media; follow the manual’s media-depth and drainage requirements.

Manufacturer Resources

Manufacturer contact: Warming Trends, 303-346-2224 or orders@warming-trends.com. Have the burner model, fuel type and selected package available when confirming fit or service.